Firefighter Personal Alarm (Standalone Model)
Category:
[Zhengze Technology] The firefighter distress beacon is compact and easy to wear. During rescue operations, if a rescuer falls or becomes trapped, it automatically triggers an audible and visual alarm to indicate their location, enabling other responders to quickly pinpoint their position and initiate rescue efforts, thereby ensuring the safety of rescue personnel.
The device emits clear, distinctive alarm signals that can be rapidly and reliably detected even in the harshest conditions, making it an essential tool for firefighters and emergency responders in hazardous environments.
Service Hotline:400-966-1998
Product Details
The Zhengze firefighter distress beacon is compact and easy to wear. During rescue operations, it can automatically emit audible and visual alerts if the rescuer falls or becomes trapped. The device alerts users to their location, enabling other rescuers to quickly pinpoint their position and carry out rescue operations, thereby ensuring the safety of rescue personnel.
The device can emit clear, distinctive alarm signals that ensure rapid and effective identification even in the harshest environments, making it ideal for fire‑fighting and rescue operations. Critical equipment used by relief personnel in hazardous environments.
Zhengze Technology’s four standalone firefighter distress beacons:

Product Features:
- Complies with the GB 27900-2011 national standard.
- Upon power-up, the system automatically checks the device status and activates the alarm light and buzzer.
- It features a high-strength polycarbonate inner shell, offering waterproof, explosion-proof, crush-resistant, and high-temperature‑resistant properties.
- High-decibel audible alarm and high-brightness visual alarm.
- Timekeeping function, providing precise timing for firefighters entering the fire scene.
- The position‑light function, with a luminance exceeding 300 cd/m², ensures safety for firefighters in heavy smoke conditions.
- Environmental temperature detection and display function; when the temperature exceeds 80°C, the device will trigger a high-temperature alarm.
- Battery level detection and display, with a low-battery warning feature.
- Black box functionality facilitates data retrieval and analysis, providing historical records of various faults and alarm messages.
- Protection rating: ≥IP68.

Firefighter Personal Alarm RHJ1500/A: ≥1500 minutes of continuous alarm time; lightweight, with flashlight-assisted illumination.
Firefighter distress beacon RHJ1800/A: ≥1800 minutes of continuous alarm time; ultra-long standby, eliminating the need for frequent charging.
Firefighter Emergency Beacon RHJ500/B: ≥500 minutes of continuous alarm duration; extra-large button design for easy operation.
Firefighter Emergency Alarm RHJ680/A: ≥680 minutes of continuous alarm time, ergonomically contoured waist design for a comfortable grip.
Application scenarios:
Based on the core functions of the Zhengze firefighter personal alarm devices (RHJ1500/A, RHJ1800/A, RHJ500/B, RHJ680/A) ( Static alarm, high-temperature warning, loud audio‑visual alert, precise timing, IP68 protection ), Its critical role in the “last line of defense for life” is applied in the following key scenarios:
1. Rescue operations for personnel lost or unconscious during interior fireground attacks: When firefighters enter a burning structure to fight fires or conduct search-and-rescue operations, they may experience extremely poor visibility due to thick smoke, or lose consciousness, fall, and become immobilized as a result of high temperatures, oxygen deprivation, or structural collapse. Equipment value : Automatically triggered, Precise positioning, High-temperature warning.
2. Work in confined spaces and underground facilities: In confined, enclosed spaces such as underground utility tunnels, subway tunnels, mine shafts, or building rubble, communication signals may be obstructed, and secondary collapses or entrapment of personnel are likely to occur.
3. Nighttime and Complex-terrain Search and Rescue: During nighttime mountain and wilderness search-and-rescue operations, water rescues, or at large-scale disaster sites, poor lighting and complex terrain can easily cause rescuers to become separated from their teams or suffer falls and injuries.
4. High-Intensity Training and Real-World Exercises: When fire departments conduct live‑fire simulations, physical‑fitness assessments, or tactical coordination exercises, they must precisely monitor each team member’s physiological condition and work duration.
5. Hazardous Chemical Leakage and Special Disaster Response: When responding to high‑risk scenarios such as toxic gas leaks or the dispersion of radioactive materials, rescue personnel must don heavy protective suits, which significantly impede mobility and pose extremely high risks.
Consult now to receive a customized rescue plan.
Service Hotline: 400-966-1998
Business Cooperation: business@nj-zhengze.com